language

18 Years Factory Heat Recovery System In Buildings - Plate Fin Type Crossflow Total Heat Exchanger – Holtop

Products Detail
The corporation upholds the philosophy of "Be No.1 in excellent, be rooted on credit rating and trustworthiness for growth", will proceed to provide aged and new buyers from home and abroad whole-heatedly for small airflow ERV, industrial hvacr , heat recovery ventilation , Created solutions with brand price. We attend seriously to produce and behave with integrity, and because of the favor of clients in your own home and overseas in the xxx industry.
18 Years Factory Heat Recovery System In Buildings - Plate Fin Type Crossflow Total Heat Exchanger – Holtop Detail:

HOLTOP Plate Fin Type Crossflow Total Heat Exchanger

Holtop Cross-flow Plate Fin Total Heat Exchangers ( Enthalpy Recovery core for energy recovery ventilator)

Product Description:

Total heat exchanger is made of ER paper which is featured by high moisture permeability, good air tightness, excellent tear resistance, and aging resistance. The clearance between the fibers is very small, so only the moisture molecules of small diameter can go through, the odor molecules of larger diameter are unable to pass through it. By this means, the temperature and humidity can be recovered smoothly, and prevent the pollutants infiltrating to the fresh air.

  

Main Feature:

1. Made of E.R. paper, which is featured by high moisture permeability, good air tightness, excellent tear resistance, and aging resistance.
2. Structured with flat plates and corrugated plates.
3. Two air streams flow crossly.
4. Suitable for room ventilation and industrial ventilation system.
5. Heat recovery efficiency up to 85%

 

 total heat enthaply air to air crossflow heat exchanger for energy recovery ventilatortotal heat enthaply air to air crossflow heat exchanger for energy recovery ventilator

Working principle

The flat plates and the corrugated plates form channels for fresh or exhaust air stream. When the two air steams passing through the exchanger crossly with temperature difference, the energy is recovered.

 total heat enthaply air to air crossflow heat exchanger for energy recovery ventilator

 

Performance index

total heat enthaply air to air crossflow heat exchanger for energy recovery ventilator

 

E.R. paper performance introduction

 Heat exchange paper: for heat and moisture exchange, the main performance standards are diathermancy, moisturepenetrability and air permeability. Corrugated paper: to construct the frame for the heat exchanger, flowing passages of the air stream.
Anti-bacteria and mold prevent performance

The bacteria exists in the damp air, when air goes through the heat exchanger, bacteria may stick on the walls of the exchanger. If the heat exchanger doesn’t have the anti-bacteria ability, it will grow on the inside wall, and then blown into indoor, which will cause indoor air pollution. That is why the anti-bacteria performance is required. The ability of bacterial growth inhibition and killing bacteria, to prevent the production of mold, is an important factor of heat exchanger paper. By adding the bactericides to the surface of paper and the anti-bacteria agents to the slurry, the heat exchanger has abilities to kill bacteria (such as Escherichia coli and staphylococcus) and inhibit fungal (such as Candida albicans) and prevent the bacteria and germ spreading in the air. Holtop heat exchanger paper was tested by Guangzhou Industry Microbe Test Center, and shown the antibacterial effect, and its mildew grade is 0.
total heat enthaply air to air crossflow heat exchanger for energy recovery ventilator

 

Product Specification 

 

The heat exchange paper and corrugated paper are adhesived with waterborne binder, the core and cover are sealed with special sealant to total separate the supply air and exhaust air, in order to keep the structure strength and air tightness and prevent the cross contamination. It is widely applied and the maximum temperature should not exceed 100 C.
For size A within 500mm and the size L within 600mm, the heat exchanger is built in one module. For size A bigger
than 500mm and size L bigger than 600mm, the heat exchanger is built in multi-modules.

Model A (mm) B (mm) C (mm) Optional corrugation height (mm) Remarks
HBT-W168/168 168 ≤500 240 2.0, 2.5 One module
HBT -W202/202 202 ≤500 288 2.0, 2.5
HBT -W222/222 222 ≤500 317 2.0, 2.5
HBT-W250/250 250 ≤700 356 2.0, 2.5, 3.5
HBT-W300/300 300 ≤700 427 2.0, 2.5, 3.5
HBT -W350/350 350 ≤700 498 2.5, 3.5
HBT -W372/372 372 ≤700 529 2.5, 3.5
HBT -W400/400 400 ≤700 568 2.5, 3.5
HBT -W472/472 472 ≤550 670 3.5
HBT -W500/500 500 ≤550 710 3.5
HBT -W552/552 552 ≤550 783 3.5
HBT -W600/600 600 ≤550 851 3.5
HBT -W652/652 652 ≤550 925 3.5
HBT -W700/700 700 ≤550 993 3.5 Multi-module combined
HBT -W800/800 800 ≤550 1134 3.5
HBT-W1000/1000 1000 ≤450 1417 3.5
HBT-W1200/1200 1200 ≤450 1702 3.5
HBT -W1400/1400 1400 ≤450 1985 3.5
HBT -W1600/1600 1600 ≤450 2265 3.5

 total heat enthaply air to air crossflow heat exchanger for energy recovery ventilator

Applications

Used in comfortable air conditioning ventilation system and technical air conditioning ventilation system. Supply air and exhaust air totally separated, heat recovery in winter and cold recovery in Summer

-Direct air to air energy exchange

-Ideal for both residential and commercial application

- Suitable for airflow 300-60000 m3/h.

  • Previous: Cross Counterflow Heat Exchangers
  • Next: Sensible Plate Heat Exchanger

Product detail pictures:

18 Years Factory Heat Recovery System In Buildings -
  Plate Fin Type Crossflow Total Heat Exchanger – Holtop detail pictures

18 Years Factory Heat Recovery System In Buildings -
  Plate Fin Type Crossflow Total Heat Exchanger – Holtop detail pictures

18 Years Factory Heat Recovery System In Buildings -
  Plate Fin Type Crossflow Total Heat Exchanger – Holtop detail pictures

18 Years Factory Heat Recovery System In Buildings -
  Plate Fin Type Crossflow Total Heat Exchanger – Holtop detail pictures

18 Years Factory Heat Recovery System In Buildings -
  Plate Fin Type Crossflow Total Heat Exchanger – Holtop detail pictures

18 Years Factory Heat Recovery System In Buildings -
  Plate Fin Type Crossflow Total Heat Exchanger – Holtop detail pictures


Related Product Guide:

We depend on sturdy technical force and continually create sophisticated technologies to meet the demand of 18 Years Factory Heat Recovery System In Buildings - Plate Fin Type Crossflow Total Heat Exchanger – Holtop , The product will supply to all over the world, such as: Accra , South Korea , Yemen , We attained ISO9001 which provides solid foundation for our further development. Persisting in "High quality, Prompt Delivery, Competitive Price", we have established long-term cooperation with clients from both overseas and domestically and get new and old clients' high comments. It is our great honor to meet your demands. We are sincerely expecting your attention.