Commercial Building Big House Mechanical Ventilation Units with Total Heat Exchanger

● Energy Recovery Ventilation System

● Comfort Fresh Air + Heat Rcovery Energy Saving

● Ceiling Suspened Instllation
● Airflows: 600m3/h~1300m3/h
● EPS Inner Structure

● Higher Efficiency Enthalpy Exchanger

● Good Thermal Insulation

● BLDC motors
● New Primary Filter

● Sub-HEPA F9 Filter Integrated Optional

● Touch Screen Intelligent Controller 

Products Detail

“Quality 1st, Honesty as base, Sincere company and mutual profit” is our idea, in an effort to create consistently and pursue the excellence for Popular Design for Light Commercial Building Big House Mechanical Ventilation Units with Total Heat Exchanger, Hope we can easily generate a more glorious potential along with you by means of our endeavours within the long run.
“Quality 1st, Honesty as base, Sincere company and mutual profit” is our idea, in an effort to create consistently and pursue the excellence for China Heat Recovery Ventilation and Heat Recovery Unit, We have now gained a lot of recognition among customers spread all across the world. They trust us and always give repetitive orders. Furthermore, mentioned below are some of the major factors that have played significant role in our tremendous growth in this domain.
HOLTOP CEILING MOUNTED ERV WITH BYPASS FUNCTION AND PM2.5 FILTRATION

 

 

energy saving erv

Fresh air supply + High Efficiency Purification+ Energy recuperative

( reducing running cost of cooling or heating air conditioning system)

 

 Energy recovery ventilation (ERV) is the energy recovery process of exchanging the energy contained in normally exhausted building or space air and using it to treat (precondition) the incoming outdoor ventilation air in residential and commercial HVAC systems. During the warmer seasons, the system pre-cools and dehumidifies while humidifying and pre-heating in the cooler seasons. The benefit of using energy recovery is the ability to meet the ASHRAE ventilation & energy standards, while improving indoor air quality and reducing total HVAC equipment capacity.

1

Higher Energy Efficiency and Ecology by Powerful Motors
HOLTOP XHBQ-D*DCPMTHC Series Commercial energy recovery ventilators is built with higher efficiency BLDC motors, power consumption is reduced by up to 70%, resulting in significant energy saving. Advanced Intelligent control is suitable for most of the projects’ air volume and ESP requirements.

 

ECO SMART PRO DC MOTOR
Higher efficiency with Holtop 3rd generation enthalpy exchanger (Total heat Recuperator)Holtop crossflow enthalpy exchanger, heat recovery efficiency up to 82% in winter, the allowance of moisture exchange between fresh air and exhaust air make a soft indoor temperature and humidity.The 3rd generation enthalpy exchanger is made of the latest nanofiber structure to ensure higher efficiency. The heat exchange materials are mildew resistance and fire retardant. 

enthalpy exchangerECO SMART PRO A

Good thermal insulation

The whole series is integrated with EPS structure, effectively preventing condensation, and improving thermal insulation and saving energy consumption.

New Primary Filter
New primary filter is made of aluminium alloy frame and rubber filtration materials with nice appearance and longer service life.
Sub-HEPA F9 Filter Integrated Optional
Optional sub HEPA F9 filter, particle diameter under 2.5μm can be filtered effectively, IAQ (indoor air quality) will be increased obviously
.2
New compact structure
New airflow channels are to increase heat exchange surface and improve energy recovery efficiency.
New compact structure
Easy maintenance
• Regular access door is for maintenance of primary filter, PM2.5 filter and heat exchangers.

• Increase two professional access doors for the control and fan maintenance.
easy maintenance
Specifications4 5Selection Guide

1. Choose the proper installation types based on the building structure

2. Determine the fresh airflow required according to the use, size and number of persons

3. Select the right specifications and quantity according to the determined fresh airflow

 

2021 New Product 600 m3/h EPS inner structure fresh air exchanger recuperator

 

 

Example

The area of a computer room is 60 sq. meters (S=60), the net height is 3 meters (H=3), and there are 10 per-sons (N=10) in it.

If it is calculated according to “Personal fresh air consumption”, and assume that: Q=70, the result is

Q1 =N*Q=10*70=700(m3/h)

If it is calculated according to “Air changes per hour”, and assume that: P=5, the result is

Q2 =P*S*H=5*60*3=900(m3)

Since Q2 > Q1 , Q2 is better for selecting the unit.

 

As to special industry such as hospitals (surgery and the special nursing rooms), labs, workshops, airflow re-quired should be determined in conformity with regulations concerned.

Holtop Factory certificaiton

“Quality 1st, Honesty as base, Sincere company and mutual profit” is our idea, in an effort to create consistently and pursue the excellence for Popular Design for Light Commercial Building Big House Mechanical Ventilation Units with Total Heat Exchanger, Hope we can easily generate a more glorious potential along with you by means of our endeavours within the long run.
Popular Design for China Heat Recovery Ventilation and Heat Recovery Unit, We have now gained a lot of recognition among customers spread all across the world. They trust us and always give repetitive orders. Furthermore, mentioned below are some of the major factors that have played significant role in our tremendous growth in this domain.