language

Factory selling Air Conditioning System - Holtop Condensing Exhaust Heat Recovery Air handling Units – Holtop

Products Detail
In an effort to finest meet up with client's requirements, all of our operations are strictly performed in line with our motto "High High quality, Competitive Rate, Fast Service" for air purification and Dehumidification , 300cmh ERV , air conditioning syestem , We welcome customers, business associations and friends from all parts of the world to contact us and seek cooperation for mutual benefits.
Factory selling Air Conditioning System - Holtop Condensing Exhaust Heat Recovery Air handling Units – Holtop Detail:

微信图片编辑_20211117140754

 High standard configuration and reliable operation

微信图片编辑_20211117140742

 Total heat recovery core, patented technology, high efficiency energy saving

The heat recovery efficiency is over 92%. The indoor exhaust with low temperature and low humidity is used as the cooling air of the (evaporative) condenser, which makes use of both the sensible heat (temperature difference) of the indoor exhaust and the latent heat (humidity difference) of the indoor exhaust. The condensation effect is much better than the direct use of outdoor air as the cooling air, avoiding the energy loss caused by air conversion ventilation. Similarly, when the ventilation mechanism is hot, the high-temperature and high humidity air discharged from the room is used as the heat exchange heat source on the evaporator side. Compared with the traditional central air conditioning system, the fresh air load energy consumption is saved by about 50%, and the sensible heat exchange type (optional) has higher efficiency.

微信图片编辑_20211117145642

 Fresh air conditioning, indoor air quality controls 

The equipment directly processes the fresh air introduced from the outside, and discharges the indoor polluted air caused by human activities and building materials outdoors. The fresh air exhaust is an independent channel. Air isolation heat exchange can not only meet the control and regulation requirements, but also ensure the absolute freshness of the air, and fundamentally eliminate the cross pollution of the air. At the same time, the equipment can also be equipped with ozone disinfection, ultraviolet sterilization and high-voltage electrostatic dust removal, which is suitable for hospitals and other places with high requirements.

微信图片编辑_20211117140716

No need extra independent ventilation system

In the transition season, fresh air is used to bear the indoor load, and only the supply and exhaust fans are operated to realize automatic ventilation without starting the compressor. At the same time, there is no need to configure an independent ventilation system, so the energy-saving effect is more obvious. When the temperature meets the design requirements but the humidity cannot be met, only fresh air can be treated without starting the air conditioning host system.

No need extra cooling tower and outdoor units

The equipment is designed in an integrated structure, without outdoor unit, cooling tower and high-power cooling water pump. The power distribution of fan and water pump significantly reduces the initial investment of the project and has higher efficiency. The evaporative condensing unit adopts the tubular evaporative condensing technology, makes full use of the evaporation of the water film on the surface of the fins, and can realize the cooling and condensation of the working medium in the condenser through mass transfer and heat transfer.

Cooling system under independent fresh air condition

Compared with the conventional chilled water system, the evaporation temperature of the ventilator is 8 ~ 10 ℃ higher, and there is no need for the secondary heat exchange of chilled water to transfer the cooling capacity, and the refrigeration energy efficiency ratio is increased by more than 30%.

 

Advanced control, safe and reliable

The full Chinese LCD page and microcomputer intelligent controller are selected, with advanced control, complete functions and high degree of electromechanical integration. It can realize the functions of unit start and stop program management, timing control, full-function fault alarm and fault self diagnosis. The controller has perfect automatic control function and strong anti-interference ability, and has phase loss, phase sequence and three-phase imbalance. Multiple protections such as compressor overload, fan overload, start-up delay and abnormal exhaust pressure.

 


Product detail pictures:

Factory selling Air Conditioning System -
 Holtop Condensing Exhaust Heat Recovery Air handling Units – Holtop detail pictures

Factory selling Air Conditioning System -
 Holtop Condensing Exhaust Heat Recovery Air handling Units – Holtop detail pictures


Related Product Guide:

With our excellent management, strong technical capability and strict quality control system, we continue to provide our clients with reliable quality, reasonable prices and excellent services. We aim at becoming one of your most reliable partners and earning your satisfaction for Factory selling Air Conditioning System - Holtop Condensing Exhaust Heat Recovery Air handling Units – Holtop , The product will supply to all over the world, such as: Miami , Barcelona , Qatar , Faced with the vitality of the global wave of economic integration, we are confident with our high-quality products and sincerely service to all our customers and wish we can cooperate with you to create a brilliant future.
  • The sales person is professional and responsible, warm and polite, we had a pleasant conversation and no language barriers on communication.
    5 Stars By Flora from Mexico - 2017.08.16 13:39
    Products and services are very good, our leader is very satisfied with this procurement, it is better than we expected,
    5 Stars By Gail from Rotterdam - 2018.09.23 17:37
    Write your message here and send it to us