Holtop fabrica primarius in Sinis est qui specialitas in aere ad apparatum recuperandi caloris aeris. Cum condita anno 2002, dedicata est investigationi et technicae evolutionis caloris recuperationis evacuationis et energiae salutaris instrumenti aeris tractandi plusquam XIX annos.
Praetorium Holtop ad pedem Beijing Montis Baiwang sita est, area 30,000 metrorum quadrata tegens. Basis vestibulum est in Zona Beijing's Badaling Development oeconomicis, area 60 iugerum obtegens. Ut notus fabrica in campo recuperationis caloris, laboratorium eius certificationem auctoritativam nationalem transiit, et validam R&D theam et justos diplomatis nationalis inventionis, in scribendis multiplicibus signis nationalibus participavit, et quasi National High selegit. -Tech conatibus Technologiae.
Holtop medias technicas technologias caloris recuperationis obtinuit, sine evolutione fructuum sicut laminae et caloris gyratorii nummulariorum, varias systemata caloris & energiae recuperationis et unitates aeris tractandi. Producta in plus quam 100 regiones et regiones exportatae sunt. Holtop cooperatur cum notis notis clarissimis vel oblationibus OEM servitii in quibus Hitachi, LG, McQuay, TRANE, Systemair, Aldes, Haier, Gree, MHI Group, Midea, Portitorem etc, apparatum ad incepta nationalia multa inclusa 2022 Olympia Hiemalia ministravit. Wuhan Cabin Hospitalium, Exhibitionis Mundus, etc. Holtop continue summum forum domesticum caloris et industriae recuperatio ventilatores.
Praecipua linea TG Series Energy Recuperatio Ventilators
Plus roboris salutaris - Potentia consummatio per 30-40% minuitur.
Melior velit – The TG series ERV construitur duplicata tabula cutis cum PU insulatione 20mm.
Innovativa structura – Novo consilio ut aer magis lenius fluat dum resistentia pressionis internae minuitur.
Improved accessum spatium design–Faciliorem cotidianam sustentationem.
Specificationsde Commercial TG Series Energy Recuperatio Ventilators
Model | XHBQ-D15TG | XHBQ-D20TG | XHBQ-D25TG | XHBQ-D30TG | XHBQ-D15PMTG | XHBQ-D20PMTG | XHBQ-D25PMTG | XHBQ-D30PMTG | |
Airflow (m*3/h) L/M/H | 1000/1500/ 1500 | 1200/2000/2000 | 2000/2500/2500 | 2500/3000/ 3000 | 1000/1500/ 1500 | 1200/2000/2000 | 2000/2500/2500 | 2500/3000/ 3000 | |
Externi Static Pressure (Pa) L/M/H | 84/135/ 163 | 110/132/ 176 | 140/170/ 200 | 150/180/ 210 | 74/125/ 153 | 95/116/ 160 | 125/155/ 185 | 135/165/ 195 | |
Enthalpy Exchange Efficens (%) L/M/H | Refrigerationem | 69/66/66 | 65/62/62 | 64/61/61 | 63/60/60 | 69/66/66 | 65/62/62 | 64/61/61 | 63/60/60 |
Heating | 74/70/70 | 73/71/71 | 72/70/70 | 71/69/69 | 74/70/70 | 73/71/71 | 72/70/70 | 71/69/69 | |
Temperature Exchange Efficens (%) L/M/H | 74/71/71 | 74/71/71 | 73/70/70 | 73/70/70 | 74/71/71 | 74/71/71 | 73/70/70 | 73/70/70 | |
Vox dB(A) @ 1.5m infra unitas L/M/H | 46/49/51 | 49/51/53 | 50/52/55 | 51/54/57 | 46/49/51 | 49/51/53 | 50/52/55 | 51/54/57 | |
Virtus Supple (V/Hz) | 220/50 | 220/50 | 220/50 | 220/50 | 220/50 | 220/50 | 220/50 | 220/50 | |
Current (A) | 3.8 | 4.8 | 6.3 | 9.0 | 3.8 | 4.8 | 6.3 | 9.0 | |
Potentia input (W) | 785 | 1020 | 1300 | 1950 | 785 | 1020 | 1300 | 1950 | |
Net Pondus (Kg) | 110 | 112 | 130 | 142 | 115 | 117 | 137 | 150 |