Our pursuit and firm aim should be to "Always fulfill our buyer requirements". We carry on to produce and structure top-quality excellent solutions for equally our aged and new consumers and accomplish a win-win prospect for our consumers as well as us for VRF system , Heat recovery ventilation system , hospital air handling units , We welcome shoppers, business enterprise associations and close friends from all sections with the globe to contact us and seek cooperation for mutual added benefits.
Low MOQ for Air Handling Hvac Units - Hospital Digital Intelligent Fresh Air Ventilation System – Holtop Detail:

Requirement for Ventilation of Hospital

air safety Requirement of Air SafetyHospitals are public places where bacteria and virus carriers are most densely populated, and are considered to be gathering places for pathogenic microorganisms. Not only patients carry various viruses, but hospital staff also have the opportunity to carry bacteria and viruses. Therefore, the air in the hospital must be kept circulating and highly purified to avoid cross-infection.
air-quality Requirement of Air QualityThe patient is a vulnerable group and has poor resistance. Indoor air circulation will obviously affect their recovery, and even an important factor. Hospitals need good indoor air quality to improve the treatment environment and allow patients to recover faster.
energy saving Requirement of Energy ConsumptionHospital construction is a big consumer of energy. The energy consumption of the air-conditioning system accounts for more than 60% of the total energy consumption of the building. A high-efficiency and energy-saving air-conditioning system solution should not only meet the ventilation requirements, but also effectively reduce the energy consumption of the air-conditioning.
intelligent Requirement of Intelligentization Intelligentization is an inevitable trend in the development of hospital buildings. Such as equipment centralized control and management, real time monitoring of energy consumption, automated operation & on-demand of ventilation system. Intelligentization has become an important manifestation of the medical environment and the quality of hospitals.It is also an important part of green buildings. 

The internal ventilation of hospital needs independent area control, different areas need different ventilation, and the airflow control is more complicated. In general, there are four principles:

Fresh air is introduced from the outdoor or clean area, enters the semi-polluted area, and then enters the polluted area through the pressure difference until it is discharged outdoors, effectively avoiding backflow. Meet the fresh air demand of health hospital staff and patients. At the same time, consider factors such as air exchange rate and air pressure difference in the polluted area to ensure that the fresh air flow is very sufficient.
Maintain the continuity of the 24-hour fresh air supply, pay more attention to the air flow in the hospital, and continue to maintain air quality. By monitoring the air quality and automatically adjusting the fresh air and exhaust air intelligently according to the air quality sensor, each room can be controlled individually or by the master control system, saving energy and time to the greatest extent.

Ventilation Requirement in Different Areas of Hospital

untitled In the office and duty room, the fresh air volume can be calculated according to the air circulation ratio of 4-5 times/hour to determine the exhaust air volume and maintain the positive indoor pressure.
In the conference room, the fresh air volume can be calculated according to the density of 2.5m2/person or 40m3/hour*person to determine the exhaust air volume and maintain the positive pressure in the room.
1 Taking into account the needs of nursing staff and patients, the fresh air volume can be calculated according to the standard of 50-55m³/bed in the public ward, 60m³/bed in the children’s ward, and 40m³/bed in the infection ward, to determine the exhaust air flow and maintain negative pressure.
ward The fresh air flow in the corridor (where only air supply is needed) maintains a slight negative pressure at a ventilation rate of 2 times per hour; and 10-15 times per hour for negative pressure in toilets and dirt institutions.

hospital ventilation

untitled

Digital Intelligent Fresh Air Ventilation System

Whether the system design is complete and the function configuration is reasonable will directly affect the efficiency of the entire system. At the same time, it will also have a great impact on the front-end investment and operating costs. Therefore, Holtop will select projects based on high standards, high performance, high configuration, and low cost.Digital Intelligent AHUDigital Intelligent Fresh Air Ventilation System

Digital Intelligent Fresh Air Ventilation System

According to the characteristics of different types of buildings and the needs of users, ventilation systems of different forms and different economic standards can be designed.
For example, in a hospital ventilation system that is usually divided into clean, semi-polluted, and contaminated areas, the stepwise air pressure should be differentiated in each area to control the flow of air from the clean area to the polluted area and prevent the free spread of high-risk air.
air pressure


Product detail pictures:

Low MOQ for Air Handling Hvac Units -
 Hospital Digital Intelligent Fresh Air Ventilation System – Holtop detail pictures

Low MOQ for Air Handling Hvac Units -
 Hospital Digital Intelligent Fresh Air Ventilation System – Holtop detail pictures

Low MOQ for Air Handling Hvac Units -
 Hospital Digital Intelligent Fresh Air Ventilation System – Holtop detail pictures

Low MOQ for Air Handling Hvac Units -
 Hospital Digital Intelligent Fresh Air Ventilation System – Holtop detail pictures


Related Product Guide:

We are ready to share our knowledge of marketing worldwide and recommend you suitable products at most aggressive costs. So Profi Tools offer you finest benefit of money and we are ready to produce alongside one another with Low MOQ for Air Handling Hvac Units - Hospital Digital Intelligent Fresh Air Ventilation System – Holtop , The product will supply to all over the world, such as: Lithuania , Lahore , America , During in 11 years, We've participated in more than 20 exhibitions, obtains the highest praise from each customer. Our company has been devoting that "customer first" and committed to helping customers expand their business, so that they become the Big Boss !
  • The factory workers have rich industry knowledge and operational experience, we learned a lot in working with them,we are extremely grateful that we can encount a good company has excellent wokers.
    5 Stars By Arlene from America - 2018.02.12 14:52
    The supplier abide the theory of "quality the basic, trust the first and management the advanced" so that they can ensure a reliable product quality and stable customers.
    5 Stars By Doris from Finland - 2017.06.19 13:51
    Write your message here and send it to us