HOLTOP-Modular Air Cooled Chiller (Heat Pump)
Reliable operation
1.Integrated Protection
Integrated protection by more than 10 protection measures to guarantee the stable and high efficiency operation
2.Double Anti-freezing protection
Holtop air cooled heat pump, unit has two double anti-freeze protections: Water pump running anti-freezing and Unit heating and anti-freezing.
3.Failure backup
One unit adopts a multi-compressor design. When one of the compressors fails, the rest of the compressors in the system can still operate normally without affecting the normal use of the entire system.
Module combination
1.Module intelligent defrosting
Holtop air cooled heat pump, unit accurately judges the frosting situation through multi-variable parameters and enter the defrosting mode intelligently, concentrate the heat of the system to melt the frost layer to the maximum extent, and shorten the defrosting time. Avoid problems such as insufficient defrosting or frequent defrosting. When heating in severe low temperature environment, manual forced defrosting can be set. The unit adopts a multi-compressor system, which can realize alternate defrosting; when multiple units are combined, the units are mutually backed up, and the units are defrosted at intervals. The number of defrosting systems does not exceed half of the total number of systems to ensure that the water temperature is stable to meet heating needs. Eliminate the phenomenon of indoor side blowing cold wind, to ensure the comfort of use
2.Modular combination
Modular design, and there is no need to distinguish between master and slave units when combining modules, which is convenient for installation. The unit can control the main machine through the wire controller, and can expand up to 15set slave machines, which can meet the load requirements of different buildings, and different series of models can be combined for joint control.
3.Flexible application
Investment:Flexible for further extension, lower investment ininitial project stage.
Transportation:The unit is small in size and can be transported independently without large hoisting equipment.
Installation:Just install it in a well-ventilated place, no special machine room and cooling water system are required. The water inlet and outlet design at the end of the unit is more conducive to reducing the installation space on site.
System:In addition to the traditional constant water flow system, the terminal circulation system can also be designed as a primary pump variable water flow system.
Intelligent control
1.Optional PLC control system
2.Intelligent Combination Control Function
3.Free Access to Building Management System
Holtop also has the Holtop Total Heat Recovery Type Air Cooled Chiller (Heat Pump). If you’re interested, click on the title above to get more product details!
At Holtop, we are committed to providing the most suitable cooling and ventilation solutions for projects. export@holtop.com.cn