Ordinary Discount Heat Exchanger Unit - Plate Fin Type Crossflow Total Heat Exchanger – Holtop Detail:
HOLTOP Plate Fin Type Crossflow Total Heat Exchanger
Holtop Cross-flow Plate Fin Total Heat Exchangers ( Enthalpy Recovery core for energy recovery ventilator)
Total heat exchanger is made of ER paper which is featured by high moisture permeability, good air tightness, excellent tear resistance, and aging resistance. The clearance between the fibers is very small, so only the moisture molecules of small diameter can go through, the odor molecules of larger diameter are unable to pass through it. By this means, the temperature and humidity can be recovered smoothly, and prevent the pollutants infiltrating to the fresh air.
Main Feature:
1. Made of E.R. paper, which is featured by high moisture permeability, good air tightness, excellent tear resistance, and aging resistance.
2. Structured with flat plates and corrugated plates.
3. Two air streams flow crossly.
4. Suitable for room ventilation and industrial ventilation system.
5. Heat recovery efficiency up to 85%
Working principle
The flat plates and the corrugated plates form channels for fresh or exhaust air stream. When the two air steams passing through the exchanger crossly with temperature difference, the energy is recovered.
Performance index
E.R. paper performance introduction
Heat exchange paper: for heat and moisture exchange, the main performance standards are diathermancy, moisturepenetrability and air permeability. Corrugated paper: to construct the frame for the heat exchanger, flowing passages of the air stream.
Anti-bacteria and mold prevent performance
The bacteria exists in the damp air, when air goes through the heat exchanger, bacteria may stick on the walls of the exchanger. If the heat exchanger doesn’t have the anti-bacteria ability, it will grow on the inside wall, and then blown into indoor, which will cause indoor air pollution. That is why the anti-bacteria performance is required. The ability of bacterial growth inhibition and killing bacteria, to prevent the production of mold, is an important factor of heat exchanger paper. By adding the bactericides to the surface of paper and the anti-bacteria agents to the slurry, the heat exchanger has abilities to kill bacteria (such as Escherichia coli and staphylococcus) and inhibit fungal (such as Candida albicans) and prevent the bacteria and germ spreading in the air. Holtop heat exchanger paper was tested by Guangzhou Industry Microbe Test Center, and shown the antibacterial effect, and its mildew grade is 0.
Product Specification
The heat exchange paper and corrugated paper are adhesived with waterborne binder, the core and cover are sealed with special sealant to total separate the supply air and exhaust air, in order to keep the structure strength and air tightness and prevent the cross contamination. It is widely applied and the maximum temperature should not exceed 100 C.
For size A within 500mm and the size L within 600mm, the heat exchanger is built in one module. For size A bigger
than 500mm and size L bigger than 600mm, the heat exchanger is built in multi-modules.
Model | A (mm) | B (mm) | C (mm) | Optional corrugation height (mm) | Remarks |
HBT-W168/168 | 168 | ≤500 | 240 | 2.0, 2.5 | One module |
HBT -W202/202 | 202 | ≤500 | 288 | 2.0, 2.5 | |
HBT -W222/222 | 222 | ≤500 | 317 | 2.0, 2.5 | |
HBT-W250/250 | 250 | ≤700 | 356 | 2.0, 2.5, 3.5 | |
HBT-W300/300 | 300 | ≤700 | 427 | 2.0, 2.5, 3.5 | |
HBT -W350/350 | 350 | ≤700 | 498 | 2.5, 3.5 | |
HBT -W372/372 | 372 | ≤700 | 529 | 2.5, 3.5 | |
HBT -W400/400 | 400 | ≤700 | 568 | 2.5, 3.5 | |
HBT -W472/472 | 472 | ≤550 | 670 | 3.5 | |
HBT -W500/500 | 500 | ≤550 | 710 | 3.5 | |
HBT -W552/552 | 552 | ≤550 | 783 | 3.5 | |
HBT -W600/600 | 600 | ≤550 | 851 | 3.5 | |
HBT -W652/652 | 652 | ≤550 | 925 | 3.5 | |
HBT -W700/700 | 700 | ≤550 | 993 | 3.5 | Multi-module combined |
HBT -W800/800 | 800 | ≤550 | 1134 | 3.5 | |
HBT-W1000/1000 | 1000 | ≤450 | 1417 | 3.5 | |
HBT-W1200/1200 | 1200 | ≤450 | 1702 | 3.5 | |
HBT -W1400/1400 | 1400 | ≤450 | 1985 | 3.5 | |
HBT -W1600/1600 | 1600 | ≤450 | 2265 | 3.5 |
Applications
Used in comfortable air conditioning ventilation system and technical air conditioning ventilation system. Supply air and exhaust air totally separated, heat recovery in winter and cold recovery in Summer
-Direct air to air energy exchange
-Ideal for both residential and commercial application
- Suitable for airflow 300-60000 m3/h.
- Previous: Cross Counterflow Heat Exchangers
- Next: Sensible Plate Heat Exchanger
Product detail pictures:
Related Product Guide:
We not only will try our greatest to supply outstanding services to every shopper, but also are ready to receive any suggestion offered by our buyers for Ordinary Discount Heat Exchanger Unit - Plate Fin Type Crossflow Total Heat Exchanger – Holtop , The product will supply to all over the world, such as: Rwanda , Jordan , Guatemala , With the intensified strength and more reliable credit, we are here to serve our customers by providing the highest quality and service, and we sincerely appreciate your support. We will endeavor to maintain our great reputation as the best products supplier in the world. If you have any questions or comments, please contact with us freely.
By Michelle from Hongkong - 2017.03.08 14:45
The customer service staff's attitude is very sincere and the reply is timely and very detailed, this is very helpful for our deal,thank you.
By Eileen from Iran - 2018.06.26 19:27